![]() Wood side plates and steel flitch plates shall be continuous throughout the span. Span, L, is center to center of supports.Tabulated values are based on ASTM A36 structural steel plate.For Spruce-Pine-Fir lumber using the tabulated flitch plate allowable loads will be slightly conservative. Design values used were published by the American Wood Council in an addendum to NDS dated March 2013. Lumber species and grade is #2 Southern Pine intended for an in-service moisture content of 19% or less.span 12 uniform load 700 plf calculate the capacity of diameter bolt. Effective span for bending and deflection is clear span plus 3 inches.įLITCH PLATE BEAM ALLOWABLE LOADS IN POUNDS PER LINEAR FOOT a, b, c, d, e (2) 2 × 6 with Plate Indicated Flitch Plate Beam Load Table - Uniform Load (plf). Values tabulated for Southern Pine are based on design values published by the American Wood Council in an addendum to NDS dated March 2013. span tables LP SolidStart rafter span tables LP SolidStart web holes v Download all. Values tabulated are for Spruce-Pine-Fir, not Spruce-Pine-Fir (South). Table Flitch Beam Hyne Beam 15C Substitution Table LVL 16 v Download all.Support for the member ends must provide a continuous load path from the bearing to the foundation. Adequate bearing and lateral support for the member must be provided.Load duration factor used in calculations is 1.0. ![]()